Stability test chamber
FitoClima 1200 PH (Stability with optional double glazed door)

Fitoclima 600 & 1200 Stability

Temperature and Humidity chambers with 600 or 1200 liters of internal volume are designed for Stability testing under all ICH conditions. It is developed for the pharmaceutical industry stability requirements, but also suitable for cosmetic products, as well as food & beverages companies.

Category: .
  • Ready to use. No assembly needed
  • Minimal footprint, for efficient use of laboratory space
  • Future proof design. The interior can be reconfigured at any time for the most efficient use of the available storage space and content dimensions
  • Content protection, with configurable high / low temperature and humidity alarms and automatic email notifications
  • Remote diagnostics, allowing a fast and accurate technical support
  • FDA 21 CFR part 11 compliant software
  • Compliant and recognized by ICH, FDA, GMP and other leading industry standards
  • Common applications include: Pharmaceuticals, Food and Beverages, Cosmetics, Veterinary, Storage and Conservation & Quality control and Research
TECHNICAL DATA
PARAMETERS FitoClima 600 FitoClima 1200
Internal volume (litres) 600 1200
temperature range 5ºC to 45ºC
temperature precision ± 0,5ºC
temperature uniformity ± 1,0ºC
humidity range 35 to 90% RH
humidity precision ± 1% RH
humidity uniformity ± 2% RH
shelves (standard configuration) 4 stainless steel wire shelves  8 stainless steel wire shelves
standard wire shelf size 640mm x 520mm
storage 0.33m2 and 18 Kg weight load (per shelf)
External dimensions(HxWxD) (mm) 1.980 x 720 x 945 1.975 x 1.440 x 810
Internal dimensions(HxWxD) (mm) 1.330 x 600 x 650 1.330 x 1.320 x 650
Weight 175 kg 250 kg
storage (standard configuration) FitoClima 600: 1,33 m22
airflow

0.2 m/s uniform across the shelves

INSTALLATION REQUIREMENTS
Water (for models with humidity control) Distilled or demineralized water. 1 to 5 bar pressure and ≤ 10μ siemens conductivity.
Water drain Advisable: located at floor level and near the equipment, with a minimum inclination of 10° from chamber to drain
Electrical connection 1PH AC 230V ±10% 50Hz 5 to12A (depending on model)
FITOCLIMA MODELS REFERENCE – STANDARD CONTROLLED ENVIRONMENT VARIABLES
FitoClima 600/1200 P Temperature only
FitoClima 600/1200 PH Temperature and Humidity
FitoClima 600 PLH Temperature, Humidity, UV and Visible Lights
FitoClima 600 PLH-R Temperature, Humidity, UV and Visible lights. Radiometer and light sensors are integrated with the chamber for an automatic control of the irradiation exposure of test specimens